LKM Series Modbus TCP to IEC62056-21 Gateway are designed to be used with electricity meters that communicates in IEC62056-21 standard. The meters that supports IEC62056-21 standard has read out tables that has several data such as import energy, export energy, phase voltages and currents. LKM Series Modbus TCP to IEC62056-21 Gateway automatically reads that values and maps to Modbus registers. Field devices or software systems can easily read data over Modbus TCP protocol so that energy meter reading can easily be integrated to field automation systems without need of IEC62056-21 protocol implementation.

frequently bought together

BKV114

BKV114
USB to RS485 Converter With USB Type A Cable and 5V Isolated Power Output

90.00 USD

Add to Cart
BKV124

BKV124
USB to RS485 Converter With USB Type C Cable and 5V Isolated Power Output

99.00 USD

Add to Cart

LKM615 MODBUS TCP to IEC62056-21 Meter Gateway for EMH LZQJ-XC Meters, 1 x Ethernet Port, Direct Connection to the Meter

MODBUS TCP to IEC62056-21 Meter Gateway for EMH LZQJ-XC Meters, 1 x Ethernet Port, Direct Connection to the Meter

LKM615

How many units do you need?
If you buy less than 5 items you will lose your 5% discount
294.50 USD 310 USD
per unit
1472.50 USD 1550.00 USD
total price
[+] More Specifications [-] More Specifications
- 1 x 10/100 Ethernet port
- Plug and play design for EMH LZQJ-XC meters; direct replacement for Variomod XC modules for EMH meters
- Serial interface directly connected to the meter (isolated, up to 5000 VRMS isolation rating, up to 10 kVPK surge capability, overload and short-circuit protection, thermal shutdown)
- Embedded web interface
- Reads the EMH LZQJ-XC meter with IEC 62056-21 (Mode C) or DLMS/COSEM
- Reads 1 meter; Modbus TCP function only: Serial Electricity Meter to Modbus TCP Gateway (and MQTT Publisher)
- Up to 48 OBIS codes per meter profile; only the IEC 62056-21 and Generic DLMS profiles (DLMS/COSEM meters are read with the Generic DLMS profile)
- Negative meter values keep their sign; a value too large for the 32-bit register gives a fixed limit value
- Modbus TCP server with up to 10 clients at the same time
- Function code 03 (Read Holding Registers); every value is 32 bits = 2 registers, 48 values per meter row
- MQTT publisher with two data formats (OBIS VALUES AS OBJECTS and OBIS VALUES AS MODBUS FRAME), at the same time as Modbus
- Meter reading, Modbus communication and OBIS-to-Modbus mapping status, and the meter read-out data, on the web interface
- Device Status overview cards for the meters, Modbus and MQTT, each with a green, amber, red or grey dot
- White list or black list IP filter with up to 20 IP addresses (in the Modbus TCP function)
- DHCP server
- Firmware update over the web interface; 2 firmware banks in the device (1 active), the previous firmware can be started again
- Configuration backup and restore as a file
- No console connection for logs; the log goes to a UDP server
- Gets power directly from the meter (isolated, isolation voltage up to 1500 VDC)
- Operating temperature -40 to 85 C
- ABS housing, IP51, 105 x 45 x 27 mm (h x w x d)