LKM Series Modbus TCP to IEC62056-21 Gateway are designed to be used with electricity meters that communicates in IEC62056-21 standard. The meters that supports IEC62056-21 standard has read out tables that has several data such as import energy, export energy, phase voltages and currents. LKM Series Modbus TCP to IEC62056-21 Gateway automatically reads that values and maps to Modbus registers. Field devices or software systems can easily read data over Modbus TCP protocol so that energy meter reading can easily be integrated to field automation systems without need of IEC62056-21 protocol implementation.

frequently bought together

BKV312

BKV312
USB 2.0 to 2 Port Ethernet Switch With USB Type A Cable

120.00 USD

Add to Cart
BKV322

BKV322
USB 2.0 to 2 Port Ethernet Switch With USB Type C Cable

129.00 USD

Add to Cart

LKM154-Lite MODBUS TCP to IEC62056-21 Protocol Meter Gateway, 1 x Ethernet Port and 1 x RS485 Port

MODBUS TCP to IEC62056-21 Protocol Meter Gateway, 1 x Ethernet Port and 1 x RS485 Port

LKM154-Lite

How many units do you need?
If you buy less than 5 items you will lose your 5% discount
218.50 USD 230 USD
per unit
1092.50 USD 1150.00 USD
total price
[+] More Specifications [-] More Specifications
- 1 x 10/100 Ethernet port
- 1 x RS485 port; no RS232 for the meters and for the Modbus RTU output
- Embedded web interface
- Reads electricity meters with IEC 62056-21 (Mode C), DLMS/COSEM, and DLMS/COSEM with IEC 62056-21 opening
- Meter side start baud rate selectable from 300 to 115200 baud for each meter
- 2 device functions:
  • Serial Electricity Meter to Modbus TCP Gateway (and MQTT Publisher): meters on the RS485 port, data given out as Modbus TCP (and MQTT)
  • TCP/IP Electricity Meter to Modbus RTU Gateway (and MQTT Publisher): meters on the network (IP address and TCP port of each meter), data given out as Modbus RTU on the RS485 port (and MQTT)
- Up to 10 meters (IEC 62056-21 and DLMS/COSEM), data converted to Modbus TCP or Modbus RTU
- Up to 48 OBIS codes per meter profile, 6 profiles (IEC 62056-21, Landis+Gyr DLMS, Actaris/Itron, Iskra DLMS, Cewe DLMS, Generic DLMS), all set from the web interface
- Several IEC meters on one RS485 line: a read-out that comes from another meter than the one asked is not stored
- Negative meter values keep their sign; a value too large for the 32-bit register gives a fixed limit value
- Modbus TCP server with up to 10 clients at the same time, or Modbus RTU output from 300 to 460800 baud
- Function code 03 (Read Holding Registers); every value is 32 bits = 2 registers, 48 values per meter row
- MQTT publisher with two data formats (OBIS VALUES AS OBJECTS and OBIS VALUES AS MODBUS FRAME), at the same time as Modbus
- Meter reading, Modbus communication and OBIS-to-Modbus mapping status, and the meter read-out data, on the web interface
- Device Status overview cards for the meters, Modbus and MQTT, each with a green, amber, red or grey dot
- White list or black list IP filter with up to 20 IP addresses (in the Modbus TCP function)
- DHCP server
- Firmware update over the web interface; 2 firmware banks in the device (1 active), the previous firmware can be started again
- Configuration backup and restore as a file
- No console connection for logs; the log goes to a UDP server
- 9 - 36 V DC power input (40 V maximum)
- Operating temperature -40 to 85 C
- Rugged metal IP-40 housing
- DIN-rail mounting

  • Payment Options

    Bank wire transfer option is available. Please contact us with your company commercial details for this method.

  • Delivery

    We ship worldwide via Express shipment. It takes maximum 2-3 days to deliver. It is always possible to use customer courier account and please contact us for that specific requirements.

  • Money back guarantee

    We offer you money back guarantee if you do not satisfy with the quality and performance of our probes.