LKM Series Modbus TCP to IEC62056-21 Gateway are designed to be used with electricity meters that communicates in IEC62056-21 standard. The meters that supports IEC62056-21 standard has read out tables that has several data such as import energy, export energy, phase voltages and currents. LKM Series Modbus TCP to IEC62056-21 Gateway automatically reads that values and maps to Modbus registers. Field devices or software systems can easily read data over Modbus TCP protocol so that energy meter reading can easily be integrated to field automation systems without need of IEC6056-21 protocol implementation.

LKM254

MODBUS TCP to IEC62056-21 Protocol Meter Gateway

LKM254

¿Cuántos puertos ópticos necesitas?
Si compra menos de 5, perderá el 5% de descuento.
275.50 USD 290.00 USD
Para uno puerto óptico
1377.50 USD 1450.00 USD
Precio Total
[+] Más información [-] Más información
-    100 - 240V AC (120 – 370V DC), 50Hz to 60Hz Wide Range AC Power Input
-    Supports 2 x 10/100Base-T(X) ports
-    Supports 1 x RS232 and 1 x RS485 Serial Connection up to 115200 Baud
-    Embedded web interface for ease of use
-    2 different Gateway Operating Modes:
     Serial IEC Meter to Modbus TCP Gateway with MQTT Publisher
     TCP/IP IEC Meter to Modbus RTU Gateway with MQTT Publisher
-    Up to 20 IEC Meter reading and conversion of their data to Modbus TCP or RTU conversion 
-    Reading up to 48 OBIS Registers and all user configurable from web interface
-    MQTT Publisher with different data transfer options
     OBIS Values as Data Objects
     OBIS Values as Modbus Frame
-    Easy to follow Meter Reading and Modbus Communication status from web interface
-    Easy to follow OBIS to Modbus mapping status from web interface
-    Easy to follow Meter Read Out Data from web interface
-    White List or Black List based IP filter up to 20 IP Addresses
-    Firmware Upgrade over Web
-    2 firmware storage capability on same device (1 active only)
-    Wide operating temperature range from -25 to 70 °C
-    Rugged Metal IP-40 housing design
-    DIN-Rail mounting

  • Formas de pago

    También hay una opción de pago mediante transferencia bancaria. Para este método, contáctenos con los detalles de su empresa.

  • Driver

    Mi Sistema oparativo
    Fecha de Lanzamiento: 2017-08-30
    X86 (32-BIT): 2.12.28
    X64 (64-BIT): 2.12.28

  • Entrega

    Enviamos a todo el mundo con envío exprés y entregamos en un máximo de 2-3 días. También es posible utilizar la cuenta de transporte del cliente, por favor, póngase en contacto con nosotros para sus solicitudes especiales.

  • Garantía de reembolso

    En caso de no estar satisfecho con la calidad y el desempeño de nuestras sondas, le garantizamos la devolución de su dinero.